Flame setting with the M.A.S.® Burner
The flame setting device is designed considering the kiln dimensions, it is operated from the burner's cold end.
The numbers on the scale of the flame setting device refers directly to the adjusted deflection angle of the M.A.S. nozzles. This numbers ranging from 0 to 10 are called "scale numbers".
| Scale number | adjustment to set |
| 0 | the longest possible flame |
| 10 | the shortest possible flame |
| any intermediate settings | flames from long to short |
![]() |
![]() |
|
![]() |
Images beside showing the possible deflection of the M.A.S. hoses maximal 0° up to 40° deflection |
![]() |
| Air adjustment for a long flame M.A.S. hose deflection approx. 10° Scale number 1,5 | Air adjustment for a short flame M.A.S. hose deflection approx. 35° Scale number 8,4 |
VIDEOCLIPS
The adjustment of the M.A.S. air pressure setting is used to obtain sharp or soft flames.