Burner Accessories
Ignition Burner
For rotary kiln burners the installation of an ignition burner is obligatory according to EN 746-2 for operation without visual supervision.
| Ignition fuel: Kind of ignition: Flame control: Ignition air: |
Natural Gas, Propane Gas or Diesel High voltage Ionisation rod taken from primary air, no additional fan necessary |

Internal Flame Scanner
We provide an "internal flame scanning" enabling a direct view into the flame. Malfunctions (loss of flame signal) caused by clinker dust are prevented in this way. The optical lens is protected from heat by internal cooling air.
The unit consists of:
Optical lens with fiber optic cable.
Flame scanner, mounted on burner Evaluation unit to be installed in a control box.

Pneumatic Lance Retractions
To protect fuel lances from overheating it may be useful to equip one more lance carrier ports with a lance retraction device to retract a lance automatically when operation has been stopped.
The unit consists of:
Pneumatic cylinder
Solenoid valve for actuation
Limit switches (retracted/inserted)
Guiding bars with lever